北亿纤通荣誉产品
Cisco 2-Channel SFP WDM Transponder参数详解

产品分类:兼容思科系列

F-TONE Technology版权所有
  • 模块封装:
  • 模块波长:
  • 更新时间:2014-12-27 20:01
  • 官方网址:http://www.f-tone.com
  • 数据手册:请联系我们sales获得
  • 购买须知

    ☉推荐兼容品牌:                                
    H3C 华三 ZTE 中兴 Huawei  CSICO 思科 ZYXEL 合勤 HP 惠普 zyxel合勤 Linksys
    DCN extrem  RedBack  Juniper  3COM Ruijie  Netgear ALPHQ
    Bdcom  D-link  Avaya alcatel   AlliedTelesis  Intel  Nortel SMC
    Dell Emulex Enterasys Feixun Force10 Brocade Adtran IPTIME
    Hirschmann IBM Asante Motorola Linksys Marconi Foundry Maipu
    McAfee Blade Nortel Planet Q-logic SMC IP-COM Asante
    SUN Telco TRENDnet Vixel Broadcom Marvell TENDA TP-link
    磊科 HILLSTONE XIRCOM 水星网络 欣全 VIGOR 港湾 AMD
    侠诺 艾泰 飞鱼星 博威 五舟 摩羯 Marvell Samsung
    宝德 飞迈瑞克 JCG Altera 世纪飞扬 浪潮 清华同方 华硕/联想
    注:购买时请说明你想用那个厂家的设备,谢谢!

    ☉如果需要详细的数据手册,请联系我们的SALES,谢谢!
    ☉如果应用中遇到什么问题,请联系我们的FAE,我们将为你提供更多 、更好的资源!
     

    CONTENT

    The Cisco® 2-Channel SFP WDM Transponder expands the range of applications and platforms supported by coarse wavelength-division multiplexing (CWDM) and dense wavelength-division multiplexing (DWDM) pluggable optics solutions from Cisco. It supports any client, any protocol, and any speed between 155 Mbps (OC-3/STM-1) and 2.488 Gbps (OC-48/STM-16).

    Product Overview

    The Cisco 2-Channel SFP WDM Transponder (Figure 1) is an unmanaged unit that can be used to convert any incoming optical signal into a CWDM or DWDM channel. Its flexibility in terms of data rates, protocols, and wavelength-division multiplexing (WDM) options is provided by Cisco pluggable optics, which reside on both the client side and the trunk side.
    In addition, when Small Form-Factor Pluggable (SFP) devices with the same wavelength reside on client and trunk sides, the unit can be simply used as a 3R regenerator (re-amplification, reshaping and retiming) for the uplink data stream (client to network path) and a 2R regenerator (re-amplification and reshaping) for the downlink data stream (network to client path), turning it into a very dynamic and flexible module.

    Figure 1. Cisco 2-Channel SFP WDM Transponder

    The transponder effectively extends the range of client devices that can connect to the CWDM or DWDM network using pluggable optics: third-party SONET/SDH add/drop multiplexers (ADMs), storage and Ethernet devices, or Cisco platforms that do not support pluggable WDM optics can connect to the WDM network by using this transponder, which operates the wavelength conversion from older 850/1300/1550 nanometer (nm) signals to any CWDM or DWDM channels. This conversion is enabled by the WDM SFP ports sitting on the line side (Figure 2).

    Figure 2. SFP Ports on the Transponder

    Each transponder supports up to two CWDM or DWDM line SFP optics (plugged into the ports labeled "NTWK1" and "NTWK2") as well as two client SFP optics (plugged in the ports labeled "EQPT1" and "EQPT2"). The range of Cisco SFP optics on the transponder supports any protocol and speed between 155 Mbps and 2.488 Gbps.
    The transponder is compatible with the passive Cisco CWDM chassis (Figure 3) (part number CWDM-CHASSIS-2=). Two transponder devices can coexist together in the two-slot chassis. There is no limit to the number of chassis that can be stacked in a rack. Alternatively, the transponder can coexist in the same chassis with any Cisco CWDM passive filters.

    Figure 3. Cisco CWDM Chassis

    Table 1 lists the compatible SFP optics required by each application.

    Table 1. Supported SFP Optics and Applications

     

     

    Client Protocol

    Bit Rate (Mbps)

    Client SFP (Product Number)

    CWDM Line SFP (Product Number)

    DWDM Line SFP (Product Number)

    SONET/SDH

    2488

    SFP-OC48-SR

    SFP-OC48-IR1

    SFP-OC48-LR2

    • CWDM-SFP-1470=
    • CWDM-SFP-1490=
    • CWDM-SFP-1510=
    • CWDM-SFP-1530=
    • CWDM-SFP-1550=
    • CWDM-SFP-1570=
    • CWDM-SFP-1490=
    • CWDM-SFP-1610=

    32 channels

    • DWDM-SFP-3033=
    • DWDM-SFP-3112=

    -

    • DWDM-SFP-XXXX=

    -

    • DWDM-SFP-5979=
    • DWDM-SFP-6061=

    622

    SFP-OC12-SR

    SFP-OC12-IR1

    SFP-OC12-LR1

    SFP-OC12-LR2

    SFP-OC12-MM

    155

    SFP-OC3-SR

    SFP-OC3-IR1

    SFP-OC3-LR1

    SFP-OC3-LR2

    SFP-OC3-MM

    • ONS-SE-155-1470=
    • ONS-SE-155-1490=
    • ONS-SE-155-1510=
    • ONS-SE-155-1530=
    • ONS-SE-155-1550=
    • ONS-SE-155-1570=
    • ONS-SE-155-1590=
    • ONS-SE-155-1610=

    -

    Gigabit Ethernet

    1250

    GLC-LH-SM=

    GLC-SX-MM=

    GLC-ZX-SM=

    GLC-BX-D=

    GLC-BX-U=

    SFP-GE-L=

    SFP-GE-S=

    SFP-GE-Z=

    • CWDM-SFP-1470=
    • CWDM-SFP-1490=
    • CWDM-SFP-1510=
    • CWDM-SFP-1530=
    • CWDM-SFP-1550=
    • CWDM-SFP-1570=
    • CWDM-SFP-1490=
    • CWDM-SFP-1610=

    32 channels

    • DWDM-SFP-3033=
    • DWDM-SFP-3112=

    -

    • DWDM-SFP-XXXX=

    -

    • DWDM-SFP-5979=
    • DWDM-SFP-6061=

    Fibre Channel

    1063

    DS-SFP-FC-2G-LW=

    ONS-SE-G2F-LX=

    DS-SFP-FC-2G-SW=

    ONS-SE-G2F-SX=

    2125

    DS-SFP-FC-2G-LW=

    ONS-SE-G2F-LX=

    DS-SFP-FC-2G-SW=

    ONS-SE-G2F-SX=

     

    Applications

    The transponder is designed for situations where most of the equipment operates directly with pluggable optics, but a few platforms without WDM pluggable optics need to connect to the WDM network. Figure 4 shows an example of two sites connected through SONET links: The transponders at each location take the signals from the SONET equipment and convert them to CWDM channels, which communicate with passive Cisco CWDM devices.

    Figure 4. Example Deployment Scenario

    Product Specifications

    The Cisco 2-Channel SFP WDM Transponder is an unmanaged unit that runs no software. The front-panel LEDs (Figure 5) report various alarm conditions as summarized in Table 2. Tables 3 to 6 list product and optical specifications.

    Figure 5. Front-Panel LEDs

    Table 2. LED Descriptions

     

     

    Led Name

    Color

    Description

    POWER

    Green

    Power on

    Off

    Power off

    EQPT1/2 TX

    Green

    Equipment 1 laser on

    Red

    Equipment 1 laser off

    Off

    Equipment 1 SFP not present

    EQPT1/2 RX

    Green

    Equipment 1 signal detected

    Red

    Equipment 1 loss of signal

    Flashing green

    Equipment 1 loss of lock

    Off

    Equipment 1 SFP not present

    NTWK1/2 TX

    Green

    Network 1 laser on

    Red

    Network 1 laser off

    Off

    Network 1 SFP not present

    NTWK1/2 RX

    Green

    Network 1 signal detected

    Red

    Network 1 loss of signal

    Off

    Network 1 SFP not present

     

    Table 3. Product Specifications

     

     

    Configuration

    Parameter

    Specification

    Electrical

    Supply voltage

    90-240VAC

    Max power consumption

    9.7W

    Connector type

    IEC 60320 C14 inlet plug

    Reliability

    Mean time between failures (MTBF)

    24.68 years

    Mechanical

    Dimensions

    • 6.91 in. (faceplate 8.25 in. ) W
    • 1.6 in. H
    • 10 in. D

    Weight (estimated with 4 SFPs)

    4-5 lb

    Environmental

    Temperature

    0-40º C

    Performance

    Bit rate

    100-2500 Mbps

    Regeneration

    • 3R upstream (from client to trunk SFP)
    • 2R downstream (from trunk to client)

     

    Table 4. CWDM SFP Optical Specification (OC-3/STM-4, OC-48/STM-16, 1G Ethernet, 1G Fiber Channel and 2G Fiber Channel)

     

     

    Parameter

    Symbol

    Minimum

    Maximum

    Units

    Notes and Conditions

    Transmitter Center Wavelength

    λ

    (λ - 4)

    (λ + 7)

    nm

    Available center wavelengths are 1470, 1490, 1510, 1530, 1550, 1570, 1590, and 1610 nm

    Side-Mode Suppression Ratio

    SMSR

    30

     

    dB

     

    Transmitter Optical Output Power

    Pout

    0

    5.0

    dBm

    Average power coupled into single-mode fiber

    Receiver Optical Input Power (BER < 10-12 with PRBS 2-7-1)

    Pin

    -29.0

    -7.0

    dBm

    Data rate below 2000 Mbps

    Receiver Optical Input Power (BER < 10-12 with PRBS 2-7-1)

    Pin

    -28.0

    -7.0

    dBm

    Data rate above 2000 Mbps

    Receiver Optical Input Wavelength

    λ

    1450

    1620

    nm

     

    Transmitter Extinction Ratio

    OMI

    9

     

    dB

     

    Dispersion Penalty at 100 km

       

    2

    dB

    Data rate below 2000 Mbps

    Dispersion Penalty at 100 km

       

    3

    dB

    Data rate above 2000 Mbps

     

    Table 5. CWDM SFP Optical Specification (OC-3/STM-1)

     

     

    Parameter

    Symbol

    Minimum

    Maximum

    Units

    Notes and Conditions

    Transmitter Center Wavelength

    λ

    (λ-4)

    (λ + 7)

    nm

    Available center wavelengths are 1470, 1490, 1510, 1530, 1550, 1570, 1590, and 1610 nm

    Transmitter Optical Output Power

    Pout

    0

    5.0

    dBm

    Average power coupled into single-mode fiber

    Receiver Optical Input Power (BER <10-12 with PRBS 2-7-1)

    Pin

    -34.0

    -7.0

    dBm

    at 155 Mbps

    Receiver Optical Input Wavelength

    λ

    1450

    1620

    nm

     

    Dispersion Penalty at 100 km

       

    1

    dB

    at 155 Mbps

     

    Table 6. DWDM SFP Optical Specification (OC-3/STM-4, OC-48/STM-16, 1G Ethernet, 1G Fiber Channel and 2G Fiber Channel)

     

     

    Parameter

    Symbol

    Minimum

    Maximum

    Units

    Notes and Conditions

    Transmitter

    Spectral Width

       

    0.2

    nm

    Full width, -20dB from maximum, with resolution bandwidth (RBW) = 0.01 nm

    Transmitter Center Wavelength

    λ

    λ - 100

    λ + 100

    pm

    Center wavelengths are in-line with Cisco DWDM channel plan and 100GHz ITU grid

    Side-Mode Suppression Ratio

    SMSR

    30

     

    dB

     

    Transmitter Extinction Ratio

    OMI

    8.2

     

    dB

     

    Transmitter Optical Output Power

    Pout

    0

    4.0

    dBm

    Average power coupled into single-mode fiber

    Receiver

    Receiver Optical Input Wavelength

    λ

    1530

    1565

    nm

     

    Receiver Damage Threshold

       

    -1

    dBm

     

    Dispersion Tolerance

     

    -500

    1600

    ps/nm

     

    Power-Limited Performance at OSNR of 20 dB (< 2000 Mbps) or 21 dB (> 2000 Mbps) at 0.1-nm RBW

    Optical Input Power

    Pin

    -28.0

    -9.0

    dBm

     

    Dispersion Power Penalty < 2000 Mbps

       

    3

    dB

    -800/+3600 ps/nm

    Dispersion Power Penalty > 2000 Mbps

       

    3

    dB

    -800/+2400 ps/nm

    Noise-Limited Performance at OSNR of 18 dB (< 2000 Mbps) or 19 dB (> 2000 Mbps) at 0.1-nm RBW

    Optical Input Power

    Pin

    -22.0

    -9.0

    dB

     

    Dispersion OSNR Penalty < 2000 Mbps

       

    2

    dB

    -800/+3600 ps/nm

    Dispersion OSNR Penalty > 2000 Mbps

       

    3

     

    -800/+2400 ps/nm

     

    Ordering Information

    To place an order, visit the Cisco ordering homepage. Table 7 lists ordering information for the Cisco 2-Channel SFP WDM Transponder.

    Table 7. Ordering Information

     

     

    Product Name

    Part Number

    Cisco 2-Channel SFP WDM Transponder

    WDM-SFP-2CH-CONV=

    上一篇:Cisco 10GBase DWDM XENPAK Modules参数详解   下一篇:Cisco CWDM GBIC and SFP Solution参数详解

    产品展示